GE E2000 Miniature Circuit Breakers

GE E2000 Miniature Circuit Breakers

GE E2000 Miniature Circuit Breakers

SCS is a stocking distributor for the GE E2000 Miniature Circuit Breakers. In this blog we will be highlighting the EP100 ULC and the EP100ULHC series MCB’s. GE E2000 Miniature Circuit Breakers (MCB) offer superior supplemental overload and short circuit protection. The GE E2000 Miniature Circuit Breakers line has two levels of interruption capacity, 6 kAIC and 10 kAIC, at 480Y/277. The GE E2000 Miniature Circuit Breakers provide application flexibility with their small size and modularity. They are DIN rail mounted in one-, two-, three and four-pole construction. The GE E2000 Miniature Circuit Breakers are Component Recognized and are CE marked.

 

GE E2000 Miniature Circuit Breakers Features and Benefits
• Dual AC & DC Ratings
• 6 kAIC & 10 kAIC Interruption Ratings @480Y/277 Vac
• B Trip Characteristics from 5 to 63 A
• C & D Trip Characteristics from 0.5 to 63 A
• Standard North American 5, 15, 30 & 60 A Ratings
• Left & Right Side Accessory Mounting – up to 4 per side
• E35 mm DIN-rail Mounting
• UL Recognized & CSA Approved

GE E2000 Miniature Circuit Breakers Applications
• Power supplies/UPS
• PLC I/O points
• Lighting circuits Solenoids
• Relay/contactor coils
• Appliances
• Control circuits
• EMotor circuits

GE E2000 Miniature Circuit Breakers Performance

EP100 ULC Series (UL1077)

  • Thermal setting In – 0.5-63amp
  • Rated voltage AC Un – 277/480v
  • Minimum operating voltage UB min – 12v
  • Tripping characteristics – B-C-D
  • Selectivity class 3
  • Mechanical/electrical endurance – 20000/10000
  • Tropicalisation acc. to IEC 60068-2 – 95% RH at 55°C
  • Terminal capacity flexible/rigid cable – 25-35 mm2
  • Poles – 1,2,3,4
  • Weight – 125 (g/pole)

EP100 ULH Series (UL489)

  • Thermal setting In – 0.5-32amp
  • Rated voltage AC Un – 120/240, 110v
  • Minimum operating voltage UB min – 12v
  • Tripping characteristics – B-C-D
  • Selectivity class 3
  • Mechanical/electrical endurance – 20000/10000
  • Tropicalisation acc. to IEC 60068-2 – 95% RH at 55°C
  • Terminal capacity flexible/rigid cable – 25-35 mm2
  • Poles – 1,2,3
  • Weight – 130 (g/pole)